Capacitive point level detector, Hygienic, Ready for use: water-based liquids/with IO-Link alcohol and oil-based liquids or powdery media, Output: 3-wire PNP/DC-PNP, Process pressure range: -1–16 bar, power supply: 10–30 V DC, Process temperature range: -20–100 °C, Probe material: stainless steel (1.4404), Protection rating: IP65/IP67 or IP66/IP68/IP69K
Capacitive point level detector, Output: 3-wire PNP/DC-PNP, Process pressure range: -1–6 bar, Power supply: 12–30 V DC, Process temperature range: -20–80°C/-20–75°C for explosion-proof aparatus, Protection rating: IP65/IP67 - IP66/IP68/IP69K
Capacitive point level detector: Probe length: 6,000 mm, Process pressure range: -1–6 bar, Output: 3-wire PNP/relay, Process temperature range: -40–70°C, Enclosure material: aluminium/polyester, Protection rating: IP66
Capacitive point level detector: Probe length: 140 mm, Output: 3-wire PNP/relay, Process pressure range: -1–25 bar, Process temperature range: -40–120°C, Enclosure material: aluminium/polyester, Protection rating: IP66
Hygienic point level sensor, 2 x NC/NO programmable, DC PNP/NPN, Liquid and viscous media and powders, Protection rating: IP68/IP69K, EHEDG, FDA, 3-A, M12 connector
Capacitive point level detector, Probe length: 140 mm, Relay output, 3-wire, Power supply: 20–253 V AC/20–55 V DC, Process temperature range: -20–80 °C, Pressure measurement range: -1–25 bar, Probe material: steel HD-PE insulated, Enclosure material: aluminium, Protection rating IP66, Process connection: R 1, Cable entry: M20 cable glanding
Capacitive point level detector, Probe length: 140 mm, PNP, 3-wire, Power supply: 10.8– 45 V DC, Process temperature range: -20–80 °C, Pressure measurement range: -1–25 bar, Probe material: steel HD-PE insulated, Enclosure material: aluminium, Protection rating IP66, Process connection: R 1, Cable entry: M20 cable glanding
Capacitive point level detector, Probe length: 140 mm, Power supply: 20...253 V AC / 20...55 V DC, Process temperature range: -40...120 °C, Pressure measurement range: -1...25 bar, Switching output: Relay, Material enclosures: Transparent cover / polyester, Protection rating: IP66, Process connection: R 1, Cable entry: M20 cable glands
Capacitance point level detector with status display, Media: water-based liquids, Output: PNP/NPN, Interface: IO-Link, 3-wire, Process connection: G 1/2 external, Process pressure range: -1...25 bar, Process temperature range: -20...+100 °C, Electrical connection: M12 plug, status display
Hygienic point level sensor, 2 x NC/NO programmable, DC PNP/NPN, Liquid and viscous media and powders, Protection rating: IP68/IP69K, EHEDG, FDA, 3-A, M12 connector
Hygienic point level sensor, 2 x NC/NO programmable, DC PNP/NPN, Liquid and viscous media and powders, Protection rating IP68/IP69K, EHEDG, FDA, 3-A, M12 connector
Capacitance point level detector, Hygienic, Media: liquid, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–16 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G3/4 (316L), Connection: M12 plug connection
Capacitive point level detector, Probe length: 140 mm, PNP, 3-wire, Power supply: 10.8...45 V DC, Process temperature range: -40...120 °C, Pressure Measuring range: 0...25 bar, Switching output: 3-wire PNP 10.8...45 V DC, Protection rating: IP66, Process connection: R 1, Cable entry: thread G1/2
Capacitive point level detector, Probe length: 140 mm, PNP, 3-wire, Power supply: 10.8– 45 V DC, Process temperature range: -20–80 °C, Pressure measurement range: -1–25 bar, Probe material: steel HD-PE insulated, Enclosure material: aluminium, Protection rating IP66, Process connection: R 1, Cable entry: M20 cable glanding, ATEX approved