Conductive point level switch, Output: 2 x SPDT relay, Process temperature range: -20–60°C, Auxiliary power: 85–253 V AC/20–30 V AC/20–60 V DC, Protection rating: IP66
Conductive point level switch, Hygienic models available, Media: water and oil-based, Output: switching, Power supply: 10–30 V DC, Pressure Rating: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67/IP69K, Process connection: G/tri-clamp/metric/DN11851, Connection: valve plug or M12 connector
Conductive point level switch, Rope probe, Media: liquid, probe length: 10-590 in. (250-15,000mm), Measurement point: 2-5 rope (316Ti), Output: Switching, 3-conductor, Power supply: 10.8-45 V DC/20–253 V AC/20–55 V DC/Namur/Nivotester, Pressure rating: -1–10 bar, Process temperature range: -40–100 °C, protection rating: IP66, Process connection: NPT or G thread, Connection: cable gland
Conductive point level switch, rod probe, Media: liquid, probe length: 40-157 in. (100-4,000mm), Measurement point: 2-5 rods (stainless steel or carbon fiber), Output: switching, Power supply: 10.8-45 V DC/20-253 V DC/20-55 V DC/NAMUR/Evaluation unit, Pressure rating: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: NPT or G thread, Connection: Gland entry
Conductive point level switch, functions: two-channel fill-level analysis / level / switch delay / two-point control, switching output: 1 x SPDT fill level + 1 x SPST alarm, auxiliary energy: 20–30 V AC/20–60 V DC, dimensions: 35 x 99 x 102.5 mm, operating temperature: -20–60 °C, mounting: DIN 35 rails
Conductive point level switch, hygienic, media: water and oil-based, output: DC-PNP, 3-conductor, power supply: 10–30 V DC, pressure measurement range: -1–25 bar, process temperature range: -20–100 °C, protection rating: IP65, process connection: 1-1 1/2 " tri-clamp, connection: 1/2" NPT valve plug
Conductive point level switch, rod probe, media: liquid, probe length: 36", measurement point: 2 x rod (stainless steel), output: FEW54, 3-conductor, power supply: 20–253 V AC/20–55 V DC, pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, protection rating: IP66, Process connection: 1 1/2" NPT, Connection: 1/2" NPT gland
Conductive point level switch, rod probe, media: liquid, probe length: 20", measurement point: 2 x rod (stainless steel), output: FEW54, 3-conductor, power supply: 20–253 V AC/20–55 V DC, pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, protection rating: IP66, Process connection: 1 1/2" NPT, Connection: 1/2" NPT gland
Conductive point level switch, rod probe, media: liquid, probe length: 36", measurement point: 3 x rod (stainless steel), output: separate instrumentation (FTW325), 3-conductor, pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, protection rating: IP66, Process connection: 1 1/2" NPT, Connection: 1/2" NPT gland
Conductive point level switch, rod probe, media: liquid, probe length: 72", measurement point: 5 x rod (stainless steel), output: separate instrumentation (FTW325), 3-conductor, pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, protection rating: IP66, Process connection: 1 1/2" NPT, Connection: 1/2" NPT gland
Conductive point level switch, hygienic, media: water and oil-based, output: DC-PNP, IO-Link, 3-conductor, power supply: 10–30 V DC, pressure measurement range: -1–25 bar, process temperature range: -20–100 °C, protection rating: IP65, process connection: 2" tri-clamp, connection: 1/2" NPT valve plug